Types of data center fire declaration and extinguishing methods dynamic

Today, one of the most important things in the server room or data centers is the data center fire alarm and extinguishing system and their basic and standard design. Since today we are witnessing the growth of the country in various fields such as information technology and data security. For this reason, the data and information of public and private organizations should be well protected in the server room and data centers.

So that a lot of money is spent annually to maintain this virtual information in data centers. Therefore, protection and physical security of the data center chinese australia phone number lead fire is very important. For this reason, in this article, we will describe various methods of announcing and extinguishing data center fire in order to provide appropriate information in this field to the audience. So stay tuned with the continuation of this article!

 

How to design the notification and fire extinguishing system of datacenters

The design of any system needs to pay attention to different principles and standards. Therefore, various points should be taken into account when designing the data center fire alarm and extinguishing system. Security experts usually visit the desired location and then implement various components in the software, the most important of which are as follows:

Attention to the dimensions of the hall or room in terms of cubic meters, which includes their length, width and height.
They check the false ceiling and false floor to extract their size and height.
Paying attention to the arrangement and arrangement of the racks, which are usually in the form of a cold room or face-to-face.
Investigating how power cables pass in data centers
Paying attention to the type of cooling systems used, which usually include HK system, split cooling, etc.
Examining the city and the space where the data center exists in terms of its geographical location and its height above sea level.
Attention to the temperature of the server room or data center
Checking the concentration of the environment
Designing the notification and fire extinguishing system of datacenters
Types of data center fire declaration and extinguishing methods
The data center’s fire alarm and extinguishing system is designed in such a way that it can detect the possibility of a fire in the server room. Usually, this system gives the necessary warnings by using different methods such as sounding the alarm, calling or sending SMS. Therefore, some types of data center fire declaration and extinguishing methods are as follows:

Fire alarm and extinguishing control center

There are different zones in this center, which include three notification zones and one fire extinguishing zone. Any of these zones will activate the fire alarm system and the fire alarm will sound. If two zones operate at the same time, the fire alarm and extinguishing system is also activated and FM200 gas is discharged.

2. Smoke detector
During a fire, when the smoke goes to the ceiling, the smoke detector detects it and sends it to the fire alarm control center.

3. Push the fire alarm
If the operator is present in the server room , he can activate the alarms before the fire alarm system by pressing the fire alarm button, thus saving time.

4. Fire alarm
If a fire occurs in any of the zones, the fire alarm will sound, and as a result, everyone will be informed about the fire.

Telephone device

chinese australia phone number lead

 

If there is no one inside the data center when a fire occurs, the calling device has the ability to call the relevant authorities automatically.

6. Suction detector system
One of the best devices that measure smoke and its amount in the air by sucking the air inside the racks is the suction detector device.

This device is highly accurate and performs this operation continuously, and if smoke is detected. It immediately reports to the fire control center.

7. Thermal linear cable
Usually, these cables are produced in analog and digital ways and enable fire detection in a completely thermal way at different temperatures.

It can be said that these cables are used a lot at temperatures of 68 degrees, 86 degrees and 108 degrees.

For example, if your racks are placed next to high temperature and the cooling system is not able to cool them.

So, by connecting these cables to the data center fire extinguishing control panel, they will find the location of the fire.

8. Emergency power system

The emergency power system is one of the systems that plays an effective role in preventing data center fires. Usually, the existence of an emergency power system leads to the proper functioning of your system during a fire. Also, the presence of this system during a power outage makes the fire extinguishing and fire alarm systems of the data center work properly.

Data center fire alarm and extinguishing system impact of google core update 2024 on seo components
Datacenter fire announcement and extinguishing
Types of data center fire alarm and extinguishing systems have different components, some of which are as follows:

Use of standard piping in fire extinguishing network
Usually, in these systems, standard piping is used that follows NFPA rules. Therefore, Mannesman steel pipes are used in these pipelines, which have no seams. These pipes are connected through welding and have no threads and will be able to withstand high gas pressure.

Use of fire extinguishing gas
FM200 gas is generally used for data center fire extinguishing system.

Using a fire extinguisher cylinder or capsule
Capsules are usually used to store fire extinguishing gas. The capsule must be of high quality to prevent gas leakage and prevent it from bursting.

Electric valve
There is an electric valve on the head of the capsule.

This valve takes command from the control panel and releases the gas when it receives the command.

360 degree spray nozzle
This nozzle is usually installed at the end of the pipes so that the gas is well distributed in the room.

Manual fire extinguisher
This button provides facilities for the user to activate the fire alarm system manually.

Manual stop thumb

This feature also allows stopping the fire alarm system manually after waiting for 30 seconds.

data center
conclusion
According to the stated contents. One of the most vital components of data centers is their fire alarm and extinguishing systems.

Since the server room or data center is the place of protection of various information and data, so if this information is lost.

It causes a lot of financial and moral losses for organizations and organizations.

As you know, these rooms have electrical equipment and various appliances that generate.

Heat with continuous operation and kcrj increase the possibility of fire. Therefore, in this article, we have examined the various methods of announcing and extinguishing data. Center fire so that the audience can get to know these methods well.

 